Specifications

General

Dimensions
76.85 × 60.55 × 34 mm
Weight
Approx. 168 g
Colour
Black & red
PTT Button
Yes
VOX
None
Emergency Button
Yes
Microphone Sensitivity
-42 ±3 dB @ 1 kHz 3.0 V 2.2 KΩ; 0 dB = 1 V/Pa
Speaker Power
1.5 W (nominal); 2 W (max.)
Speaker Impedance
16 Ω ±15% @ 1.2 kHz
Frequency Response
94 ±3 dB @ 1 kHz 1 W/30 cm (300 Hz ~ 3.4 kHz AVE)
Certification
CE, IECEx, ATEX, FM
IP Rating
IP67
Explosion Resistance
IECEx (Ex ib Mb, Ex ib IIC T4 Gb, Ex ib IIIC T90℃ Db), ATEX, FM
Operating Temperature
-25℃ ~ 60℃
Storage Temperature
-40℃ ~ 85℃

Hytera SM26N13PEx Intrinsically Safe Remote Speaker Microphone — Detail

Technical assessment

Audio accessories decide whether coverage is usable. A radio heard perfectly on a bench is not heard at all over a running plant, and the resulting complaint is normally reported as poor coverage rather than as the wrong accessory.

Speaker output is 1.5 W (nominal); 2 W (max.).

PTT button: Yes. Emergency button: Yes. An emergency control that cannot be operated through the gloves worn on site is not an emergency control, which is worth testing with the actual gloves before ordering a fleet.

VOX: None. Voice-activated transmission frees both hands, and in a noisy environment it also transmits the noise — it suits quiet, hands-occupied work rather than a plant floor.

Ingress protection is IP67. Accessory connectors are where dust and moisture do their damage first; a cover that is actually used extends the life of the accessory more than the rating does.

Operating temperature range is -25℃ ~ 60℃.

We deliver not only what you need, but more than you expect .