Specifications

General

Weight
Approx. 38 g
Colour
Black
PTT Button
Yes
VOX
None
Emergency Button
None
Microphone Sensitivity
-42±3 dB @ 1 kHz 3.0 V 2.2 kΩ
IP Rating
None
Operating Temperature
-20℃ to 60℃
Storage Temperature
-20℃ to 80℃
Note
Compatible with receive-only earpieces such as the EAS05.

Hytera ACN07 PTT Microphone Cable — Detail

Technical assessment

Audio accessories decide whether coverage is usable. A radio heard perfectly on a bench is not heard at all over a running plant, and the resulting complaint is normally reported as poor coverage rather than as the wrong accessory.

PTT button: Yes. Emergency button: None. An emergency control that cannot be operated through the gloves worn on site is not an emergency control, which is worth testing with the actual gloves before ordering a fleet.

VOX: None. Voice-activated transmission frees both hands, and in a noisy environment it also transmits the noise — it suits quiet, hands-occupied work rather than a plant floor.

Ingress protection is None. Accessory connectors are where dust and moisture do their damage first; a cover that is actually used extends the life of the accessory more than the rating does.

Operating temperature range is -20℃ to 60℃.

We deliver not only what you need, but more than you expect .