Specifications

General

Weight
Approx. 375 g
Colour
Blue
PTT Button
None
VOX
None
Emergency Button
None
Connectivity
QR4 connector
Microphone Sensitivity
–50 ±4 dB @ 1 kHz 3.0 V 2.2 KΩ; 0 dB = 1 V/Pa
Speaker Power
200 mW (nominal); 500 mW (max.)
Speaker Impedance
2x150 Ω ±15% @ 1 kHz
Frequency Response
82 ±3 dB @ 1 kHz 0.2 W/50 cm
Noise Reduction
Up to 23 dB
IP Rating
IP54
Explosion Resistance
ATEX (Ex ib IIC T4, Ex ib IIIC T110℃)
Operating Temperature
-20℃ ~ 50℃
Storage Temperature
-20℃ ~ 65℃
Note
Designed for helmet mounting

Hytera POA176Ex Noise-Cancelling Helmet Headset — Detail

Technical assessment

Audio accessories decide whether coverage is usable. A radio heard perfectly on a bench is not heard at all over a running plant, and the resulting complaint is normally reported as poor coverage rather than as the wrong accessory.

Speaker output is 200 mW (nominal); 500 mW (max.).

PTT button: None. Emergency button: None. An emergency control that cannot be operated through the gloves worn on site is not an emergency control, which is worth testing with the actual gloves before ordering a fleet.

VOX: None. Voice-activated transmission frees both hands, and in a noisy environment it also transmits the noise — it suits quiet, hands-occupied work rather than a plant floor.

Ingress protection is IP54. Accessory connectors are where dust and moisture do their damage first; a cover that is actually used extends the life of the accessory more than the rating does.

Operating temperature range is -20℃ ~ 50℃.

We deliver not only what you need, but more than you expect .