Specifications

General

Dimensions
102.4 × 80.5 × 45 mm
Weight
Approx. 90 g
Charger Type
Standard
Maximum Charge Current
850 mA
Number of Bays
1
Input
12 V DC, 1 A
Operating Temperature
0℃ ~ 45℃
Certification
CE

Hytera CH10A03 Desktop Charger — Detail

Technical assessment

The unit has 1. Bay count is a shift-planning decision rather than a comfort one: a fleet that charges overnight needs one bay per radio, while a fleet running two shifts on rotated batteries needs fewer.

Charging type is Standard.

Input is 12 V DC, 1 A. Chargers belong outside any classified area — they are almost never certified for hazardous atmospheres — and in cold-store operations they belong in the warm part of the building, because charging a very cold lithium pack damages it.

Operating temperature range is 0℃ ~ 45℃.